What are our main leak detection methods?

Every application calls for the right method. Our certified team performs the four leak testing methods recognized by the American Society for Nondestructive Testing (ASNT), and helps you choose the one that matches your sensitivity requirements, parts and acceptance criteria.

Bubble leak testing

How can a simple visual method detect leaks?
• A foaming solution is applied to the test surface, or the part is immersed.
• A differential pressure is created, using a vacuum box or by pressurizing the item.
• Bubbles form at the leak location.
• Simple to set up, even in difficult field conditions.
• A qualitative method, ideal for locating leaks.

Pressure change leak testing

How does measuring pressure reveal leaks?
• Pressure or vacuum is applied to the tested item or system.
• A leak causes a measurable change in pressure over time.
• A quantitative method that measures the total leakage rate.
• Well suited to pressure vessels, piping systems, tanks and large volumes.
• Results depend on test duration, volume and temperature stability, which our technicians control and correct for.

Mass spectrometer leak testing

Why is tracer gas used for ultra-sensitive leak detection?
• A tracer gas, most commonly helium, is chosen for its very low background level in air and its inert properties.
• The tracer gas flows through even the smallest leaks, in both pressurized and evacuated systems.
• Leaks can be precisely located.
• With the right technique, the leakage rate can also be quantified.
• The most sensitive leak testing method, widely used in nuclear, aerospace, medical, automotive and manufacturing.

Halogen diode leak testing

How does halogen-based leak testing pinpoint leaks?
• A halogen-based tracer gas is introduced into the system to be tested.
• A halogen-sensitive detector reacts to the escaping gas.
• The detector signals the leak, for semi-quantitative testing.
• Commonly used in refrigeration, air conditioning and industrial applications.

Method Type of result Typical sensitivity* Best for
Bubble (BLT) Leak location (qualitative) ~10⁻³ to 10⁻⁵ mbar·L/s Welds, tank floors, field inspections
Pressure Change (PCLT) Total leakage rate (quantitative) Depends on volume, test duration and temperature stability Pressure vessels, piping, large systems
Halogen Diode (HDLT) Leak location (semi-quantitative) ~10⁻⁵ to 10⁻⁶ mbar·L/s Refrigeration, HVAC
Mass Spectrometer (MSLT) Leak location and leakage rate (quantitative) Sniffer mode: ~10⁻⁶ to 10⁻⁷ mbar·L/s
Vacuum mode: down to 10⁻¹⁰ mbar·L/s or lower
Critical, high-vacuum and hermetically sealed components

*Typical values. Actual sensitivity depends on the technique, test conditions and part. 1 mbar·L/s ≈ 1 atm·cc/s ≈ 0.1 Pa·m³/s.

With our expertise in NDT leak testing, we help you choose the best solution for your needs.